Auditorium soundproofing and acoustic treatment solutions

For auditoriums

Soundproofing and acoustic treatment for auditoriums

An auditorium is judged on one thing: whether a word spoken on stage arrives clean at the last row. That depends on how long sound lives in the room, where the rear wall sends it back, and whether the foyer can be heard through the doors.

Reverberation control
PET felt, NRC 0.30 at 9 mm to 0.60 at 24 mm
Low frequency and corners
BassBloc®, NRC 0.85 at 20 mm, 100 to 500 Hz
Isolation from the foyer
SoundBlanket® MLV, STC 34 at 4 mm
Quote
Within 48 hours, from a section, a seat count and the use

Send the plan and the long section, the hall volume and seat count, the primary use (speech, amplified music or both), the seat type and the existing wall and ceiling finishes. We manufacture and specify; we do not carry out on site acoustic consultancy, measurement or installation.

01 / What actually goes wrong

Three failures, and only one of them is about leakage

Most halls we are asked to help with are not leaking badly. They are simply too live inside, and the geometry is working against the person on stage.

  • Sound lives too long in the room

    Plaster walls, a hard ceiling and a tiled floor return energy for far longer than speech can tolerate, so each syllable is still in the air when the next one arrives. The reverberation time a hall needs depends on its volume, its seat count and whether it is used for speech or for music, which is why one absorption target for all auditoriums is wrong. What we specify against that target is absorption area: how many square metres at what NRC, and on which surfaces.

  • The rear wall and the balcony front throw sound back

    A hard rear wall square to the stage returns a single late reflection down the centre line. From the stage it is heard as a distinct echo; in the front stalls it smears consonants. The underside of a balcony and the balcony front do the same thing at shorter delays. Absorption belongs on the rear wall and the rear third of the side walls before it goes anywhere else, and the balcony soffit needs treating on its own account because the seats beneath it are shielded from the ceiling.

  • The interfaces leak, not the walls

    Foyer noise, a bar, a lobby crowd and late arrivals reach the hall through the door line, the duct openings and the junction where the wall meets the slab, not through the middle of the partition. An open area of even one per cent in an otherwise good partition sets the result. The fix is mass carried through the build-up, sealed penetrations, and sealed door sets, with an airlock at the main entrances where the plan allows one.

02 / The build-up

Three layers, in order, from the structure inwards

In a hall the third layer does most of the acoustic work, because reverberation is the problem being solved. The first two are what keep the foyer, the plant room and the street out of it.

  1. SoundBlanket 4mm sound isolation membrane for auditorium walls and ceilings

    Layer 1

    SoundBlanket® mass loaded vinyl

    The barrier, used where the hall adjoins a foyer, a corridor, a plant room or the outside. It goes inside the partition and above the ceiling line, lapped at the joints and sealed at every duct and cable penetration.

    STC 30 at 2.5 mm, STC 34 at 4 mm, to ASTM E90. 2100 kg/m³. Class A surface burning to ASTM E84. Sheets 8 x 4, 16 x 4 and 32 x 4 ft.

  2. Acoustic foam panels for targeted echo and reflection control in auditoriums

    Layer 2

    BassBloc® low frequency absorber

    The cavity layer, and the reason a hall with a full sound system does not boom. It sits behind the finish on the side and rear walls and in the wall to wall corners, and it is never left exposed.

    NRC 0.85 at 20 mm, 0.95 at 40 mm, to ASTM C423. Effective 100 to 500 Hz. 100 kg/m³, 1800 x 900 mm rolls.

  3. Acoustic finishes for auditorium diffusion absorption and premium aesthetics

    Layer 3

    The acoustic finish

    The layer that sets the reverberation time. Absorbent where reflections have to be removed, slatted or perforated where the surface has to scatter rather than swallow, and hard and reflective where energy still has to reach the back rows.

    Wooden slats NRC 0.75, EN 13501-1 Class B s1 d0  ·  Perforated NRC 0.70  ·  Pulse SoundaXe® NRC up to 0.75  ·  PET felt NRC 0.30 to 0.60, and 0.90 over 20 mm BassBloc®

3 layer wall soundproofing system diagram

The same three layers apply to the side walls, the rear wall and the ceiling void. Only the thickness and the proportion of absorbent to reflective finish change.

Layer order by surface

SurfaceFrom the structure inwardsWhat it is for
Side walls, front halfSoundBlanket® 4 mm where the wall adjoins a foyer, then slats or perforated timber over BassBloc® 20 mmScatters early reflections towards the seats instead of removing them
Side walls, rear thirdBassBloc® 20 mm with a PET felt or fabric faceTakes out the reflections that arrive late enough to smear speech
Rear wallBassBloc® 20 to 40 mm behind a PET felt or stretched fabric face, full heightKills the slap-back down the centre line to the stage
CeilingSoundBlanket® above the ceiling line where there is a room over, then baffles, clouds or tiles on the visible planeIsolation upward, and control of the overhead reflection path
Stage enclosureAbsorbent or diffusing finish on the rear and side walls of the stage, hard reflective surfaces kept forward of the performerStops the performer fighting their own reflection
Floor and doorsCarpet tiles in the aisles, perimeter and bottom seals on every hall doorFootfall and late arrivals, and the foyer path

03 / Zone by zone

Where absorption goes, and where it must not

A hall that is absorbent everywhere is as bad as a hall that is absorbent nowhere: the level drops off towards the back and the room stops supporting the performer. Placement is the whole job.

  • Auditorium walls acoustic panels and soundproofing layers

    Side walls

    The walls carry both jobs. Forward of the mid point they should scatter energy down onto the seats, so slatted and perforated timber is right. Towards the rear they should absorb, because anything returned from there arrives too late to help.

  • Ceiling acoustic treatment with baffles and panels for auditorium reverberation control

    Ceilings

    The largest single surface in the hall, and the one that decides how much energy reaches the back rows. Reflective forward of the proscenium, absorbent over the rear seating, with baffles where the services have to stay visible.

  • Auditorium floors impact noise reduction and sound isolation

    Floors and the raked seating deck

    Footfall in the aisles during a performance is an impact problem, and a hollow raked deck can drum under it. A soft aisle finish and a dense layer under the deck deal with the two separately.

  • Stage acoustic panels and fabrics for sound projection control

    Stage and backdrop

    A hard flat surface a metre or two behind a performer returns their own voice to them a few milliseconds late, which is uncomfortable to sing or speak against and audible in the front rows. Treat the back and side walls of the stage, and keep the reflective surfaces forward where they push sound out to the seats.

  • Auditorium doors and windows sealing and curtains for sound leakage control

    Doors, windows and leaks

    The hall doors open onto the noisiest part of the building. Seal the perimeter and the threshold on every leaf, and where a lobby airlock is not possible, a heavy curtain inside the door line buys back some of what the single leaf gives away.

  • Acoustic ceiling baffles for auditorium echo and reverberation control

    Audience zones and balconies

    The seats are part of the acoustic design. Upholstered seats absorb whether or not anyone is sitting in them, so a hall specified with them measures roughly the same empty as full; hard seats make the hall change character with the house size. Under a balcony the seats are cut off from the ceiling, so the soffit and balcony front have to do that work.

04 / What we see go wrong

Six mistakes that close a hall to fix

  • One absorption target for every hall

    A speech hall and an amplified music hall want different reverberation times, and a copied specification suits neither. The volume, the seat count and the primary use come first.

  • The rear wall left hard

    It is the single most audible surface in a rectangular hall and often the last one treated. The echo it returns is heard on stage and blamed on the sound system.

  • Absorption spread evenly across every surface

    Strip the front walls and ceiling of reflection and the level falls away towards the back rows. The hall then needs more amplification to do what the geometry used to do.

  • Panels installed, interfaces ignored

    Duct openings, cable routes, the wall head and the door line leak around every panel in the room. Sealing is detailing work, and it is done before the finish goes up.

  • The stage treated like the hall

    Absorption pushed too far forward takes away the support a performer relies on. The backdrop wall is the surface to treat, not the reflectors above and beside the proscenium.

  • Unrated material in a public hall

    Foam and felt with no published NRC and no fire classification discolours, sags and can fail inspection, which means stripping an occupied hall and losing its booking calendar.

05 / Specifications

Tested performance, with the standard it was measured to

ProductTested performanceTest standard
SoundBlanket mass loaded vinylSTC 30 at 2.5 mm, STC 34 at 4 mm; 2100 kg/m³ASTM E90
Echsorbix PET felt panelsNRC 0.30 at 9 mm, 0.40 at 12 mm, 0.50 at 18 mm, 0.60 at 24 mmASTM C423 / EN ISO 354
BassBloc low-frequency absorberNRC 0.85 at 20 mm, 0.95 at 40 mm; 100 kg/m³ASTM C423
MMT Acoustix acoustic foamNRC 0.90 at 50 mm (Pyramid); 0.95 at 50 mm (Galaxy)ASTM C423
SoundaXe wooden acoustic panelsNRC 0.75 (slats); 0.70 (perforated); 0.60 (fluted, 18 mm)ASTM C423

Test reports are issued with project supply. NRC and STC are the figures we publish and stand behind; a reverberation time target, a speech intelligibility figure or a hall noise rating is the scope of an acoustic consultant. The full set of reports is listed on the certifications page.

06 / Venues

Halls and performance venues we have supplied

MMTPL manufactures at its Palwal plant in Haryana and supplies performance venues, fit-out contractors and acoustic consultants in India and export markets.

  • Prithvi Theatre
  • Bahrain National Auditorium
  • NCPA National Centre for the Performing Arts
  • Regional cultural centers projects

Hall by hall detail and scope of supply are on the projects page.

07 / How we can help

What we do, and what we do not

  • We do

    • Manufacture every layer above at the Palwal plant, Haryana
    • Turn a plan, a section and a stated use into a specified build-up, a surface by surface absorption schedule and a priced BOQ, usually within 48 hours
    • Supply test reports, technical data sheets and specification text for the tender
    • Make panels to size, in custom colours and CNC patterns, including curved and raked wall runs
    • Work to a consultant's absorption schedule where one has been issued
  • We do not

    • Set or verify a reverberation time target, which needs measurement and modelling
    • Carry out on site acoustic consultancy or measurement
    • Install. We manufacture and supply the system
  • We refer

    We work with associated acoustic consultants and installers across India and can put you in touch with them for the room design, verification or execution. Ask when you send the drawings.

GET EXPERT ADVICE

Planning Acoustics for Auditoriums?

Tell us the space, the noise problem and the area involved. Our specialists will recommend the right system and share a budget estimate.

Frequently Asked Questions

What is the most common mistake in auditorium acoustics?

Treating the room surfaces but leaving the interfaces untreated. Doors, service penetrations, HVAC ducts and the junction between wall and slab leak sound around every panel you install. A 1% open area in a partition can halve its effective performance.

How much reverberation should an auditorium have?

It depends on use. Speech-led halls need a shorter reverberation time than music-led halls, which is why a single absorption target for all auditoriums is wrong. Send us the volume, the seat count and the primary use and we specify against it.

Which auditorium areas need acoustic treatment?

The main hall for reverberation, the rear wall for slap-back, the stage and proscenium for early reflections, doors and lobbies for isolation from foyer noise, and the AV and plant rooms for equipment noise.

Why do non-certified materials cost more over the life of an auditorium?

Uncertified foam and felt lose performance, discolour and can fail fire inspection, which means stripping and re-treating an occupied hall. Certified material with a test report costs more once. Replacing it costs the hall its booking calendar as well.

What products does MMTPL supply for auditoriums?

Echsorbix PET felt panels, NRC 0.30 at 9 mm rising to 0.60 at 24 mm for wall and ceiling absorption, BassBloc at 100 kg/m³, NRC 0.85 for corner and low-frequency control, SoundBlanket mass loaded vinyl, STC 30 at 2.5 mm and STC 34 at 4 mm, at 2100 kg/m³ in the wall build-up where isolation is needed, and acoustic door seals at every opening.

Who manufactures auditorium acoustic systems in India?

MMTPL (Mahabir Multi Tech Private Limited) manufactures the full range at its Palwal plant in Haryana, India, and supplies architects, consultants and turnkey contractors in India and 25+ export markets.